Lab notes: driven air-track oscillator

Notes kept in Markdown. HyperTeX reads them like any other document: the math, the tables, the task list and the footnotes all work, and links go straight to equations in the report. The measurements are simulated for illustration.

Setup

  • Cart of mass m=0.402kgm = 0.402\ \mathrm{kg} on an air track, held between two springs

  • A motor drives one spring end with a small amplitude, F0/k≈1.0mmF_0 / k \approx 1.0\ \mathrm{mm}

  • Position read by an ultrasonic sensor at 50 samples per second1

Checklist before each run:

  • ☑ Level the track (bubble level, both ends)

  • ☑ Let the cart settle for 30 s after changing the frequency

  • ☑ Record the steady amplitude, not the first swings

  • ☐ Repeat the three points nearest the peak

Free decay

Released from x0=40mmx_0 = 40\ \mathrm{mm}, the amplitude fell to half in n1/2=1.8n_{1/2} = 1.8 swings. For light damping the amplitude shrinks by e−2πζe^{-2\pi\zeta} per swing, so

Driven response

Steady amplitude relative to the static deflection F0/kF_0/k. The last column is the prediction from equation (4) of the report with f0=1.62Hzf_0 = 1.62\ \mathrm{Hz} and ζ=0.061\zeta = 0.061.

Drive ff (Hz)r=f/f0r = f / f_0Measured Xk/F0X k/F_0Predicted
0.800.4941.401.32
1.200.7412.012.17
1.400.8643.693.65
1.500.9265.405.50
1.550.9576.846.94
1.600.9888.088.13
1.621.0007.708.20
1.651.0197.657.71
1.701.0495.976.13
1.801.1114.063.69
2.001.2351.851.83
2.401.4810.820.83

The largest measured value, 8.088.08, matches the peak height 1/(2ζ1−ζ2)=8.21/(2\zeta\sqrt{1-\zeta^2}) = 8.2 from the resonance proposition within about 2%.

Resonance curves for several damping ratios

Next

Notes

  1. 1.

    The sensor has about 0.3 mm of noise, which is why the points near the peak scatter most.

    ↩